BQG-2118 Industrial Online Zirconia Oxygen Analyzer

Technical indexes


1.Measuring range: 0~20.6%02

2.Accuracy: ≤±2%FS

3.Temperature of flue gas measured: ≤600℃(low temperature type)600~800(high temperature type)

4. Excess air coefficient of flue gas measured: 0.1-99                    

5. Response time: ≤ 3 seconds (90% response)

6. Current output: 0~10mADC or 4-20mADC

7. Power supply: 220V±10% 50HZ± 5%

8.Working conditions: ambient temperature: 0~50  relative humidity:<85%

9.Heating-up time of the heater of zirconia detector: Approx 20 minutes  

10.Overall dimension and dimension of the hole



Type

Overall dimension mm

Dimension of the hole mm (height * width)

Horizontal (H)

160x80x120

152+1×76+1

Vertical (Z)

80x160x120

   76+1×152+1

Square (Q)

160x160x200

    152+1×152+1

Wall mounting (G)

220 x 170 x 75 (height x width x thickness)

BQG-2118 zirconia oxygen analyzer is practical and reliable on-line automatic oxygen analyzer. Its measurement and display system consists of an oxygen detector (sensor) and a display instrument (transmitter). The detector is made of heat-resisting and anti-corrosion materials and can be directly inserted into flues for measurement of oxygen. The display instrument adopts single-chip control and can be used in combination with various electric unit combination instrument, main display recorder instruments and distributed control systems (DCS).

Zirconia oxygen analyzer is used for rapid and accurate on-line measurement and analysis of the oxygen contents in the flue gas produced by combustion equipment, such as boilers, furnaces and heaters, so as to realize control of low-oxygen combustion, energy saving and pollution treatment. 

Features


The sensor is made of heat-resisting and anti-corrosion materials with high reliability.

With a special structural design, this analyzer doesnt need external air pump, and the reference air can realize 

convection by itself.

The sensor has a standard air interface, which enables calibration check on the site and provides convenient

maintenance.

It adopts single-chip control and data processing with quick response, accurate measurement and stable

performance.

上海博取儀器有限公司
  • 聯(lián)系人:邢銀鳳
  • 地址:上海浦東新區(qū)秀沿路118號
  • 郵箱:2355456200@qq.com
  • 手機(jī):15021885022
關(guān)注我們

歡迎您關(guān)注我們的微信公眾號了解更多信息

掃一掃
關(guān)注我們
版權(quán)所有©2025上海博取儀器有限公司All Rights Reserved    備案號:滬ICP備08017338號-29    sitemap.xml    總訪問量:668499
管理登陸    技術(shù)支持:儀表網(wǎng)
蓬溪县| 奉节县| 应城市| 孟州市| 龙泉市| 含山县| 尉犁县| 合江县| 察隅县| 永平县| 蕉岭县| 安徽省| 崇州市| 鹿泉市| 许昌市| 门源| 科尔| 金寨县| 桂阳县| 山东| 肥东县| 大洼县| 清远市| 大理市| 湄潭县| 荃湾区| 东乌珠穆沁旗| 资兴市| 静乐县| 东光县| 新宾| 日照市| 天台县| 陕西省| 闽清县| 同心县| 福安市| 冷水江市| 寿光市| 临沧市| 新巴尔虎左旗|